fsxNet Wiki

BBS Development & Resources

User Tools

Site Tools


doors:dropfiles:doorsys

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
doors:dropfiles:doorsys [2022/11/08 09:32]
avon removed
— (current)
Line 1: Line 1:
-<​code>​ 
-                             ​DOOR.SYS FORMAT'​S 
  
-FORMAT #1: 
- 
-DOORWAY recognizes 2 DOOR.SYS formats. ​ It will determine which you are using 
-if you enter SYS on the command line after DOORWAY. ​ The first is common to 
-DOORWAY, the second to several BOARD packages, such as GAP. 
- 
-Many users of other than PCBoard have asked that doorway use a simpler 
-and more consistant ASCII file for door support than PCBOARD.SYS. ​ Starting 
-with version 1.43, DOORWAY will also recognize a file by the name of DOOR.SYS. 
-I have tried to make this file as generic as possible, so others can use the 
-same format. ​ I am giving the format to Public Domain, so it may be used 
-without fear.  The following shows the file format. ​ A program reading the 
-format must be able to accept a file with additional lines, for future 
-expansion. ​ Each line is ASCII and followed by a carriage return/line feed. 
- 
- 
-USER NAME         ​* ​    This line contains the user's first and last name 
-PORT NUMBER ​      ​* ​    This line contains either a 1, 2 or 0 for local 
-BAUD RATE               This line contains the baud rate the port needs to be 
-                            opened at. 
-TIME              *     This line contains an integer less than 32767 in mins. 
-GRAPHICS ​         *     This line contains a "​G"​ for graphics, "​M"​ for mono. 
-ALARM             ​* ​    This line contains an "​A"​ for ALARM, "​S"​ for silent. 
- 
- 
- * DOORWAY will actually use this entry. ​ DOORWAY will only use the first name 
-     of the caller and will parse it from the full name. 
- 
-***************************************************************************** 
- 
-FORMAT #2: 
- 
-Added support for the "​GENERIC"​ DOOR.SYS file which follows. ​ Note 
-that it still supports the "​special"​ DOORWAY DOOR.SYS file as well.  Simply 
-put "​SYS"​ where you would put "​COM1"​ and it will read the DOOR.SYS file. It 
-will figure out which it is by looking at it. 
- 
-The "​GENERIC"​ DOORS.SYS file format follows. ​ DOORWAY only uses lines 1, 9 
-10, 19 and 20. 
- 
- 
-********************* GENERIC DOOR.SYS file format ************************* 
- 
- 
- 03/14/88 - Submitted by the "​Limited Release Software Group" 
- 
-Updated: 03/21/88 
-Updated: 10/​22/​88 ​ KG 
- 
-============================================================================= 
- 
-Sample DOOR.SYS file to be used as a STANDARD for ALL Bulletin Board Systems. 
- 
-============================================================================= 
- 
-  This file format has been laid out and will be presented to ALL BBS authors 
-in an attempt to establish a national standard for door program applications. 
- 
-BBS AUTHORS: I urge you to consider this STANDARD with respect for your 3rd 
-      party support authors. Come on guys, make life EASY for us. 
- (BIG GRIN) 
- 
-============================================================================= 
- 
-  I have tried to include EVERYTHING a 3rd party DOOR author would need to 
-provide the SYSOPS with the look and feel they want from an online program 
-while at the same time keeping things plain and simple to ease the problems 
-of interfacing programs with a system. This type of format is intended to be 
-a "​read-only"​ type of file (although it could be written again) because most 
-BBS's have some sort of other file they use for re-entering the system with 
-(PCBoard uses PCBOARD.SYS,​ GAP uses GAPDOS.DAT, Ect.) which is harder to read 
-in, and changes frequently. This file format, once established,​ wouldn'​t need 
-to be changed EVERYTIME a new version of the BBS software gets released and 
-this would also ease the demand for more info being made available in the BBS 
-Re-Entry file thus making life easier for both parties. If there is something 
-found in the following format that your BBS software may not be currently 
-supporting, a DEFAULT value has been suggested. 
- 
- 
-COM1:             <​-- Comm Port - COM0: = LOCAL MODE 
-2400              <-- Baud Rate - 300 to 38400 
-8                 <​-- Parity - 7 or 8 
-1                 <​-- Node Number - 1 to 99                    (Default to 1) 
-19200             <​-- DTE Rate. Actual BPS rate to use. 
-Y                 <​-- Screen Display - Y=On  N=Off             ​(Default to Y) 
-Y                 <​-- Printer Toggle - Y=On  N=Off             ​(Default to Y) 
-Y                 <​-- Page Bell      - Y=On  N=Off             ​(Default to Y) 
-Y                 <​-- Caller Alarm   - Y=On  N=Off             ​(Default to Y) 
-Rick Greer        <-- User Full Name 
-Lewisville, Tx.   <​-- Calling From 
-214 221-7814 ​     <-- Home Phone 
-214 221-7814 ​     <-- Work/Data Phone 
-PASSWORD ​         <-- Password 
-110               <​-- Security Level 
-1456              <-- Total Times On 
-03/​14/​88 ​         <-- Last Date Called 
-7560              <-- Seconds Remaining THIS call (for those that particular) 
-126               <​-- Minutes Remaining THIS call 
-GR                <-- Graphics Mode - GR=Graph, NG=Non-Graph,​ 7E=7,E Caller 
-23                <-- Page Length 
-Y                 <​-- User Mode - Y = Expert, N = Novice 
-1,​2,​3,​4,​5,​6,​7 ​    <​-- Conferences/​Forums Registered In  (ABCDEFG) 
-7                 <​-- Conference Exited To DOOR From    (G) 
-01/​01/​99 ​         <-- User Expiration Date 
-1                 <​-- User File's Record Number 
-Y                 <​-- Default Protocol - X, C, Y, G, I, N, Etc. 
-0                 <​-- Total Uploads 
-0                 <​-- Total Downloads 
-0                 <​-- Daily Download "​K"​ Total 
-999999 ​           <-- Daily Download Max. "​K"​ Limit 
- 
-  *****  Each line being STRAIGHT ASCII TEXT with a CR at the end.  ***** 
- 
-  Please feel free to express any comments you may have on this format, or 
-leave suggestions you have for additions to the file to..... 
- 
-     Rick Greer - SysOp of The Micromart BBS - (214) 221-7814 - 24hrs. 
- 
-</​code>​ 
-==== Source ==== 
- 
-http://​files.mpoli.fi/​unpacked/​software/​dos/​bbs/​drwy231.zip/​doorsys.doc